Home Page Home Page Multi Fuel Stoves Multi Fuel Stoves Wood Burning Stoves Wood Burning Stoves Inset Stoves Inset Stoves Contemporary Stoves Contemporary Stoves Boiler Stoves Boiler Stoves Double Sided Stoves Double Sided Stoves Smoke Control Stoves Smoke Control Stoves Limited Special Offers Limited Special Offers Flue and Chimney Materials Flue and Chimney Materials Firewood Firewood LATEST NEWS LATEST NEWS
*
Install A Stove Into an Existing Chimney with Clay liner Liners
*
*
 •  Installing a stove into an existing unlined chimney  •  Install A Stove Into an Existing Chimney with Clay liner Liners  •  Install A Stove Into A Chimney Using Flexible Liner  •  Install A Stove using internal twinwall insulated pipe  •  Install a stove using external Twinwall Insulated Pipe
*

Home
Back to Stove Installation Page
Print This Great Price


Installing A Stove Into A Chimney With Clay Liners


When you an existing clay lined chimney it is sometimes possible to connect straight into this set up. Sometimes with larger diameter clay liners it is somethings better to drop a flexible liner down inside the clay liners to reduce the chimney diameter. Check here for information on installing a flexible liner. We advise you contact a HETAS installer for professional advice

What is needed to install my woodburner?

Below you will find the products needed to install a stove into an existing unlined chimney.

1) Woodburning Stove, Multi Fuel Stove or Gas Stove
2) Single Skin Stove Pipe
3) Adaptor To Clay Liners
4) Register Plate (Can be steel or fireproof board)

Important Guidelines To Follow When Installing Your Stove

To find out what output of stove you require simply use our Online Stove Output Calculator

When determining what stove will fit into your fireplace you most follow the following guidelines:

1) You must have a gap of 150mm each side of the stove to non combustible materials and 230mm if there are combustible materials to the side.

2) You must have 230mm above the stove to non combustible materials and 460mm above the stove if there is combustible materials (for example wood)

3) You must position the stove at least 50mm from the back of the stove to the back wall.

4) Your hearth Must extend at least 225mm in front of the stoves firebox.

5) You Must also ensure that if your stove has a greater output than 5kw you must have an air vent in the room venting out to an external air source

Please note this page is designed to give you a basic idea of what is required and does not give any installation instructions as it is recommend you seek the professional advice of a Hetas installer. Click to Find a HETAS Installer

*
Site Navigation
*
*
Tel: 0844 8920136 (local rate)
Fax: 0871 5284682 (Calls cost 10 pence per minute)
Email: sales@woodburnerwarehouse.co.uk


Woodburner Warehouse
Arcade Ltd,
Fishguard Road,
Prendergast,
Haverfordwest,
Pembrokeshire,

SA61 2PQ

Opening Hours:

Monday-Friday: 9am - 4:30pm
Saturday: 9am-1pm
Sunday: Closed


Woodburnerwarehouse on Twitter


© Woodburner Warehouse 2007-2010
*
*